Smart Switch 6 Parameters

$
0
0

The Parameters for Aeons Labs Smart Switch 6 are not well documented in the manual, below you’ll find the complete parameter list.

A basic parameter setup to get feedback when the switch is manually operated and to get power readings would be:

Parameter

(dec)

Description Value
80 (1d) Status feedback to controller when manually operated

1 (Fibaro Homecenter 2/Lite)

2 (Vera Edge)

101 (4d) Auto report power readings to group 1 (Controller) 15

And the complete parameter setup is:

Parameter

Number (dec)

Description Default value Size
3 Current Overload Protection. Load will be closed when the
Current overrun (US: 15.5A, other country: 16.2A) and the
time more than 2 minutes (0=disabled, 1=enabled).
0 1
20 Configure the output load status after re‐power on
(0=last status, 1=always on, 2=always off)
0 1
33 Set the RGB LED color value for testing.
Value1: Reserved
Value2: Red value
Value3: Green value
Value4: Blue value
4
80 Enable to send notifications to associated devices (Group 1)
when the state of Switch’s load changed (0=nothing,
1=hail CC, 2=basic CC report).
0 1
81 Configure the state of LED when it is in 3 modes below:
0= The LED will follow the status (on/off) of its load (Energy
mode).
1= When the state of Switch’s load changed, The LED will
follow the status (on/off) of its load, but the red LED will
turn off after 5 seconds if there is no any switch action
(momentary indicate mode).
2= Night light mode.
0 1
83 Configure the RGB value when it is in Night light mode.
Value1: Red color value
Value2: Green color value
Value3: Blue color value
Value1=0xDD
Value2=0xA0
Value3=0xDD
3
84 Configure the brightness level of LED indication (0%‐100%) 50 1
90 Enables/disables parameter 91 and 92 below (1=enabled,
0=disabled).
1 1
91 The value here represents minimum change in wattage (in
terms of wattage) for a REPORT to be sent (Valid values 0‐
60000).
25 (w) 2
92 The value here represents minimum change in wattage
percent (in terms of percentage) for a REPORT to be sent
(Valid values 0‐100).
5 (%) 1
101 Which reports need to send in Report group 1 (See flags in
table below).
0x00 00 00 04 4
102 Which reports need to send in Report group 2 (See flags in
table below).
0x00 00 00 08 4
103 Which reports need to send in Report group 3 (See flags in
table below).
0 4
111 The time interval of sending Report group 1 (Valid values
0x01‐0x7FFFFFFF).
0x00 00 02 58 4
112 The time interval of sending Report group 2 (Valid values
0x01‐0x7FFFFFFF).
0x00 00 02 58 4
113 The time interval of sending Report group 3 (Valid values
0x01‐0x7FFFFFFF).
0x00 00 02 58 4
200 Partner ID
(0= Aeon Labs Standard Product,
1= others).
0 1
252 Enable/disable Configuration Locked (0 =disable, 1 =
enable).
0 1
254 Device Tag 0 2
255 Reset configuration set up to default setting. N/A 1

 

Configuration Values for parameter 101-103

7 6 5 4 3 2 1 0

configuration

Value 1(MSB

Reserved
configuration Value 2 Reserved
configuration Value 3 Reserved
configuration value 4 (LSB) Reserved Reserved Reserved Reserved Auto
send
Meter
REPORT
(for
kWh) at
the
group
time
interval
Auto
send
Meter
REPOR
T (for
watt)
at the
group
time
interval
Auto
send
Meter
REPORT
(for
current)
at the
group
time
interval
Auto
send
Meter
REPOR
T (for
voltage
at the
group
time
interval

 


Viewing all articles
Browse latest Browse all 107

Trending Articles


EASY COME, EASY GO


HOY PANGIT, MAGBAYAD KA!


Girasoles para colorear


Presence Quotes – Positive Quotes


Maganda Quotes – tagalog Quotes – Inggit Quotes


Mga Patama sa mga Nagmamahal the Best Tagalog love quotes for you


5 Tagalog Relationship Rules


“BAHAY KUBO HUGOT”


RE: Mutton Pies (frankie241)


Vimeo 10.7.1 by Vimeo.com, Inc.